| Performance indicators | |||
| Type of detected gas | Methane | Principle of detected | Tunable diode laser absorption spectroscopy technology (TDLAS) | 
| Detected distance | 100m | Detected range | (0~100000)ppm·m | 
| Basic error | ±1%FS | Response time (T90) | ≤0.1s | 
| Sensitivity | 5ppm.m | Protection grade | IP68 | 
| Explosion-proof grade | Exd ⅡC T6 Gb/DIP A20 TA,T6 | Detect laser safety grade | Class I | 
| Indicate laser safety grade | classⅢR (Human eyes cannot look directly) | 
 | |
| Electrical characteristics | |||
| Operating voltage | 220VAC (recommended) or 24VDC | Maximum current | ≤1A | 
| Power consumption | ≤100W | Communication | Single core optical fiber (it is recommended to lay more than 4-core optical fiber cables on site) | 
| Structure characteristics | |||
| Dimensions (Length × height × width) | 529mm×396mm×320mm | Weight | About 35kg | 
| Installation mode | Vertical installation | Material | 304 Stainless steel | 
| Environmental parameters | |||
| Environmental pressure | 80kPa~106kPa | Environmental humidity | 0~98%RH (No condensation) | 
| Environmental temperature | -40℃~60℃ | 
 | |
| PTZ parameters | |||
| Horizontal rotation | (0°±2)~(360°±2) | Vertical rotation | -(90°±2)~(90°±2) | 
| Horizontal rotation speed | 0.1°~20°/S Smooth variable speed rotation | Vertical rotation speed | 0.1°~20°/S Smooth variable speed rotation | 
| Preset position speed | 20°/S | Preset position quantity | 99 | 
| Preset position precision | ≤0.1° | Automatic heating | Automatic heating when below -10℃ | 
| PTZ control communication method | RS485 | PTZ control communication rate | 9600bps | 
| PTZ control communication protocol | Pelco protocol | 
 | |
| Camera parameters | |||
| Type of Sensor | 1/2.8" CMOS ICR day night type | Signal system | PAL/NSTC | 
| Shutter | 1/1second ~ 1/30,000 second | Day night conversion mode | ICR Infrared filter type | 
| Resolution | 50HZ:25fps(1920X1080) 60HZ:30fps(1920X1080) | Minimum illumination | Color:0.05Lux @ (F1.6,AGC ON) Black and white:0.01Lux @ (F1.6,AGC ON) | 
| Signal to noise ratio | >52dB | White balance | Auto1/Auto2/Indoor/Outdoor/Manual/Incandescent/Fluorescent | 
| 3D Noise reduction | Support | Focal length | Focal length: 4.8-120mm | 
| Aperture | F1.6-F3.5 | 
 | |
● Cloud Bench Laser Methane Detector, realize continuous scanning and monitoring in a wide range of areas with 360 ° horizontal and 180 ° vertical;
● Fast response speed, high detection accuracy, and timely find small leakage;
● It has unique selectivity for target gas, good stability and daily maintenance free;
● 220VAC working voltage, RS485 data signal output, optical fiber video signal output;
● Multi preset position setting, cruise route can be set freely;
● With special software, it can scan, locate and record the location of leakage source.
 
             
             
            